Why Your Thermostat Says 'Aux Heat' When the Temperature Drops Below Freezing
Wondering why does my heat pump say aux heat during a sudden freeze? Get clear answers on whether this thermostat mode is normal or a sign of trouble.
Waking Up to 'Aux Heat' During the First Fall Freeze
In our years of preparing Charlottesville homes for the winter at Airflow Systems, Inc., the first sudden freeze in November always brings a flurry of calls from homeowners asking the exact same question: why does my heat pump say aux heat? That sudden drop in temperature is a hallmark of our local climate, and seeing a new notification on your thermostat right before winter sets in is enough to cause any homeowner a moment of panic. You might immediately worry that your system has failed right when you need it most.
It is completely natural to be concerned about the health of your heating and cooling systems during an early November freeze. When the house feels a little different and the thermostat is flashing a new mode, you face a critical decision point: is your equipment just responding to the weather, or does it require a professional diagnostic look?
The good news is that, as our technicians often reassure our customers, in the vast majority of cases during a sudden freeze, this notification is not a warning sign. Instead, it is a built-in protective function of modern heating equipment designed to keep your family comfortable. Understanding exactly what this message means can save you from unnecessary stress and help you monitor your system with confidence as the winter weather rolls in.
What Does Auxiliary Heat Actually Mean?
To understand why that notification appears, it helps to know how your system operates. Auxiliary heat, commonly abbreviated as "Aux Heat," refers to a secondary heating source built directly into your indoor unit. These are typically electric resistance heating coils, often called heat strips. They function very much like the glowing coils inside a toaster, generating heat directly from electrical current.
How Your Heat Pump Normally Operates
Under normal conditions, your system does not generate heat; it moves it. Even when it feels chilly outside, the outdoor air still contains heat energy. The outdoor unit extracts this ambient heat, compresses the refrigerant to raise its temperature, and transfers that warmth inside your home. This process is incredibly efficient and is one of the primary advantages of a heat pump over older, traditional furnaces.
The Role of the Heat Strips
While heat pumps are highly efficient, they occasionally need a secondary heat source when external heat energy becomes too sparse. When the outdoor air gets incredibly cold, the system has to work much harder to extract enough warmth to keep your house comfortable. This is when the auxiliary heat strips step in.
You do not need to flip a switch or manually intervene. Your system is designed to seamlessly switch between the primary compressor and these secondary heat strips. The Aux Heat message is simply your thermostat's way of telling you, "I need a little extra help to reach your desired temperature, and I am turning on the backup strips to get the job done."
The Thermal Balance Point: Why Temperature Matters
The exact moment your system decides it needs help is determined by something called the thermal balance point. This is a crucial concept in HVAC design that explains why temperature matters so much to your equipment.
Understanding the Balance Point
The thermal balance point is the specific outdoor temperature threshold where your heat pump can no longer extract enough heat to keep up with the heat loss of your home. Based on the systems we install and service across Charlottesville, this balance point for most local homes occurs when you see a below 35°F outdoor temperature. At this exact threshold, the amount of heat the pump can pull from the freezing air perfectly matches the amount of heat escaping through your walls, windows, and roof.
Bridging the Heating Gap
Once the temperature drops below that balance point, the heat pump's maximum output is no longer enough to satisfy your thermostat setting. If you set your thermostat to 70 degrees, but the heat pump can only maintain 66 degrees because it is so cold outside, there is a heating gap.
To bridge this gap, the system automatically engages the electric heat strips. These strips provide the supplemental warmth needed to push the indoor temperature up to your requested 70 degrees. It is important to emphasize that this is an automatic, mathematically calculated efficiency measure. The system is doing exactly what it was engineered to do. It is not a system failure, but rather a smart adaptation to the freezing environment outside.
The Defrost Cycle: A Built-In Winter Defense
Another very common reason you will see the auxiliary heat notification is due to the system's defrost cycle. This is a built-in winter defense mechanism that protects your outdoor unit from ice damage.
How the Defrost Cycle Works
- Moisture Accumulation: During a below 35°F outdoor temperature event, there is often still moisture in the winter air. As the outdoor unit pulls air across its cold coils, this moisture condenses and can quickly freeze into a layer of frost or solid ice on the equipment.
- Cycle Reversal: If ice builds up, it blocks airflow and stops the system from working. To clear this ice, the heat pump temporarily reverses its cycle. It actually switches into air conditioning mode for a brief period, sending hot refrigerant back to the outdoor unit to melt the ice away.
- Activating Auxiliary Heat: Because the system is temporarily acting as an air conditioner, it would normally blow cold air directly into your living room. To prevent this uncomfortable blast of winter air, the system simultaneously turns on the auxiliary heat strips. The heat strips warm up the cold air before it comes out of your vents.
- Return to Normal: A typical defrost cycle only lasts between 5 to 15 minutes. Once the outdoor sensor detects that the ice has melted, the reversing valve shifts back to heating mode, the auxiliary strips turn off, and normal efficient heating resumes.
Knowing that this cycle is brief is helpful. If you see the notification, wait 15 minutes. If it turns off on its own, your system is just running its normal winter defense. Keeping up with routine HVAC maintenance ensures these sensors and reversing valves work perfectly when you need them most.
Thermostat Adjustments: The Two-Degree Rule
Sometimes, the weather isn't what triggers the auxiliary heat—it's how the thermostat is being used. Many homeowners inadvertently force their system into this less-efficient mode through manual adjustments.
The Problem: Drastic Temperature Changes
It is a common habit to turn the heat way down when leaving for work, and then crank it up by five or ten degrees as soon as you walk back in the door. While this makes sense for older furnaces, heat pumps are designed differently. They are built to maintain a steady, consistent temperature rather than make rapid, drastic changes. When you bump the thermostat up by more than two or three degrees at once, the system interprets this as an immediate, high-demand heating need.
The Cause: High-Demand Signals
The thermostat realizes that the primary heat pump compressor alone will take too long to raise the indoor temperature by five degrees. To satisfy your sudden demand quickly, it immediately activates the auxiliary strips. When our team responds to service calls asking why does my heat pump say aux heat, we frequently discover that the homeowner's own thermostat habits are the root cause. If you are constantly making large temperature jumps, you are constantly triggering the backup heat.
The Solution: Gradual Adjustments
To maximize your energy efficiency and keep the system running primarily on the compressor, follow the two-degree rule. If you want to warm up the house, increase the thermostat by only one or two degrees at a time. Wait for the system to reach that new temperature before bumping it up again. Alternatively, use a smart thermostat designed specifically for heat pumps, which can gradually bring the temperature up over time without triggering the high-demand electric strips.
Auxiliary Heat vs. Emergency Heat: Understanding the Difference
A frequent source of homeowner confusion is the difference between Auxiliary Heat and Emergency Heat. While both utilize the same electric heat strips inside your air handler, how and why they are activated are entirely different.
Understanding this distinction is vital because misusing the Emergency Heat setting can drastically alter your home's energy consumption and put unnecessary wear on your indoor components.
| Feature | Auxiliary Heat (Aux) | Emergency Heat (EM Heat) |
|---|---|---|
| Activation Method | Automatic. Controlled by the thermostat based on outdoor temperature or defrost needs. | Manual. Must be physically switched on by the homeowner at the thermostat. |
| Compressor Status | Outdoor compressor continues to run. Aux heat works alongside it to supplement warmth. | Outdoor compressor is completely locked out and shut down. It will not run at all. |
| Primary Heat Source | A blend of the efficient outdoor heat pump and the indoor electric strips. | 100% reliance on the indoor electric resistance heat strips. |
| Energy Efficiency | Moderate. Uses more energy than normal, but maximizes the efficiency of the outdoor unit. | Very Low. Electric resistance heating is the most expensive way to heat a home. |
You should never turn on Emergency Heat just because it feels cold outside. Emergency mode is reserved strictly for actual emergencies—such as if a falling branch physically crushes your outdoor unit, or if the outdoor compressor is completely frozen solid in a block of ice and non-functional. Running in Emergency mode unnecessarily will result in significantly higher energy consumption because you are completely bypassing the efficient heat pump technology you invested in.
When Does 'Aux Heat' Require a Professional Diagnostic?
While we have established that seeing this notification during a November early freeze is generally normal, there are times when it indicates a real malfunction. Knowing the difference between a normal weather response and a mechanical failure is key to protecting your home.
In our region, Charlottesville nights can easily drop below freezing, naturally triggering the backup heat. However, daytime warming should allow the primary heat pump to take over again. If it doesn't, there is an issue. Having spent countless late-fall seasons diagnosing heating systems, our team at Airflow Systems, Inc. believes in providing honest diagnostics. We want to help you verify if the system is just responding to the weather before you spend time booking a service call.
Red Flags to Watch For
- Mild Weather Operation: If the outdoor temperature is well above 40 degrees and the auxiliary notification is still running constantly, your primary compressor is likely failing to engage.
- Blowing Cool Air: If the thermostat says the backup heat is on, but the air coming out of your vents feels lukewarm or completely cold, the heat strips or the sequencer may be burned out.
- Never Shutting Off: The backup heat should cycle on and off. If it runs continuously for hours without ever taking a break, the system is struggling to satisfy the thermostat.
- Trailing Indicators: Unusually high energy bills can be a trailing indicator of a system that has been stuck in auxiliary mode for weeks without you noticing.
If you notice any of these symptoms, it is time to stop waiting for the weather to change and call for a professional Charlottesville system repair. A technician can test the reversing valve, check refrigerant levels, and ensure the heat strips are pulling the correct amperage.

Frequently Asked Questions About Heat Pump Auxiliary Heat
Because this is one of the most common concerns homeowners have during the winter, we have compiled the most frequent questions we hear when someone searches why does my heat pump say aux heat. Understanding these answers will give you a comprehensive view of your system's health.
Why is my heat pump in Aux heat mode?
Your system will automatically switch into this mode for three primary reasons:
- Outdoor temperatures have dropped below the thermal balance point (usually around 35 degrees).
- The system is running a routine defrost cycle to melt ice off the outdoor coils.
- The thermostat was manually increased by more than two degrees at one time.
In all of these scenarios, the system is functioning exactly as it was designed to, ensuring your home stays warm when the primary compressor needs assistance.
Is it bad if my heat pump says Aux heat?
It is not inherently bad; in fact, it is a brilliantly designed function to keep your home warm when the weather turns harsh. It only becomes a concern if it runs continuously during mild weather when the primary compressor should be able to handle the heating load on its own. Temporary operation during a freeze or a brief defrost cycle is completely normal and expected during the winter months.
At what temperature should Aux heat come on?
The backup heat typically activates when outdoor temperatures fall between 35 and 40 degrees Fahrenheit. However, the exact temperature varies based on the specific model of your equipment, the size of your home, and how well your house is insulated. If the temperature drops below freezing, it is almost guaranteed that the backup strips will cycle on periodically to help maintain your indoor comfort.
How do I get my thermostat off Aux heat?
If you want to test whether the system is stuck, try lowering the thermostat setting slightly (by one or two degrees) to see if the primary pump can handle the reduced load on its own. If you suspect it is in a defrost cycle, simply wait 15 minutes to allow the cycle to complete automatically. If outdoor temperatures are currently freezing, you should not try to force it off—allow the system to manage itself automatically, as it knows exactly what it needs to keep your home safe and warm.
Does Aux heat use more electricity?
Yes, electric resistance heating strips consume significantly more power than the heat pump compressor. The compressor uses a small amount of electricity to move heat, while the strips use a large amount of electricity to generate heat from scratch. This is exactly why it is used as a secondary, temporary measure rather than the primary heating source. Proper seasonal maintenance ensures your system runs efficiently and relies on the backup strips only when absolutely necessary.
Stay Comfortable and Confident This Winter
Seeing that auxiliary notification light up during a freeze doesn't have to be a source of stress. In most cases, especially when there is a below 35°F outdoor temperature, it is simply a sign that your system is working hard, protecting itself from ice, and doing whatever it takes to keep your home warm. By understanding the balance point, recognizing the short duration of a defrost cycle, and managing your thermostat adjustments gradually, you can stay comfortable and confident all season long.
However, you should always trust your instincts. If the weather warms up, but the notification remains stuck on, or if your vents are blowing cool air, don't ignore it. Monitor the system closely, and if you suspect an actual malfunction is forcing your equipment to rely on backup power, reach out for professional system repair. A quick diagnostic can restore your system's efficiency and give you true peace of mind through the coldest months of the year.
Ready When You Are.
One call reaches Charlottesville's premier WaterFurnace partner. We repair, replace, and maintain heating, cooling, and geothermal systems across Charlottesville and Central Virginia & the Blue Ridge — Mon–Fri, 7:30 AM – 4:00 PM.
- 100%Satisfaction
- FamilyOwned & operated
- M–F7:30 AM – 4:00 PM