HVAC & Geothermal Glossary — A to Z
48 plain-English definitions for the terms you'll see on a repair invoice, install estimate, or rebate application in Central Virginia & the Blue Ridge.
A
- AFUE
- Annual Fuel Utilization Efficiency — the percentage of a gas furnace's fuel that becomes useful heat over a heating season. A 95% AFUE furnace delivers 95¢ of heat for every $1 of gas. Most modern furnaces are 90–98%.
- Air Handler
- The indoor half of a split-system heat pump or AC. Contains the blower motor, evaporator coil, and filter housing. Sometimes called the 'fan coil.'
B
- BTU
- British Thermal Unit — the amount of heat needed to raise one pound of water by one degree Fahrenheit. HVAC capacity is expressed in BTU/hr; 12,000 BTU/hr = 1 ton.
- Blower Door Test
- A calibrated fan mounted in an exterior doorway that pressurizes or depressurizes the house to measure how leaky the building envelope is. Used to inform Manual J load calcs.
C
- Capacity
- The maximum rate at which a system can move heat, measured in BTU/hr or tons. A 3-ton heat pump has 36,000 BTU/hr of nominal capacity at rating conditions.
- Charge (Refrigerant)
- The precise weight of refrigerant sealed inside the system. Overcharged and undercharged systems both fail early; a proper charge is measured, not guessed.
- Closed-Loop System
- A geothermal ground-loop configuration where a sealed circuit of buried pipe carries a water-glycol mix between the earth and the heat pump. The Blue Ridge subsurface favors closed vertical loops.
- COP
- Coefficient of Performance — heating efficiency ratio. A COP of 4 means the system delivers 4 units of heat per 1 unit of electricity. WaterFurnace geothermal COPs sit around 4.0–5.3 depending on ground temp.
D
- Damper
- A movable plate inside a duct that opens or closes to redirect airflow. Motorized dampers are the mechanical foundation of zoning systems.
- Ductless
- A mini-split system: outdoor condenser + one or more indoor wall/ceiling heads, connected by small refrigerant lines. No ductwork; ideal for additions, sunrooms, and finished basements.
- Duct Static Pressure
- How hard the blower must push air through the ductwork. High static pressure means restricted, undersized, or leaky ducts and directly cuts efficiency + comfort.
E
- EER2
- The 2023-updated cooling efficiency rating measured at a single hot outdoor condition (95°F). EER2 tells you how the system performs at design load — the moment on the hottest afternoon when you need it most.
- Evaporator Coil
- The indoor coil that absorbs heat from your house air, letting the refrigerant boil into a gas. Sits inside the air handler or on top of the furnace.
- Expansion Valve (TXV/EEV)
- The metering device that controls how much refrigerant enters the evaporator. A thermostatic (TXV) or electronic (EEV) valve is required on modern high-SEER systems.
F
- Furnace
- A heating appliance that burns fuel (typically natural gas or propane in Virginia) or uses electric resistance to warm air, which the blower then distributes through ducts.
G
- Geothermal Heat Pump
- A heat pump that exchanges heat with the ground (via a buried ground loop) instead of the outdoor air. Because ground temperature stays far steadier than outdoor air, geothermal efficiency stays high in every season.
- Grille
- The visible cover on a return-air opening. Distinct from a 'register,' which is on a supply opening and has adjustable louvers.
- Ground Loop
- The buried pipe network that carries fluid between a geothermal heat pump and the earth. Loops can be vertical bores (300–400 ft typical here), horizontal trenches, or pond loops.
H
- Heat Pump
- A single system that both heats and cools by moving heat, not making it. Reverses refrigerant flow to run in either direction. Efficiency (HSPF2 for heating) beats resistance electric by 2–4x.
- HRV / ERV
- Heat Recovery Ventilator / Energy Recovery Ventilator — a device that swaps stale indoor air for fresh outdoor air while recovering most of the temperature (and, for ERVs, humidity) so you don't pay to condition the incoming air twice.
- HSPF2
- Heating Seasonal Performance Factor (2023 update) — the average heating efficiency of a heat pump across a heating season. Higher is better; the 2023 federal minimum is 7.5 HSPF2.
- Humidifier (Whole-Home)
- A device mounted on the furnace or air handler that adds moisture to the air during heating season, when indoor air can become uncomfortably dry.
I
- IAQ
- Indoor Air Quality — the overall composition of the air inside your home: humidity, VOCs, particulates, allergens, radon, CO₂. Addressed with filtration, ventilation, humidification, and dehumidification.
- Inverter Compressor
- A variable-speed compressor that ramps up or down instead of cycling on and off. Delivers dramatically better humidity control and part-load efficiency than a fixed-speed compressor.
L
- Load Calculation
- The Manual-J-driven room-by-room analysis of how much heating and cooling your home actually needs. A load calc is the difference between right-sized comfort and expensive over-sized noise.
M
- Manual J
- The ACCA-published methodology for calculating residential heating and cooling loads. A Manual J replaces rule-of-thumb square-footage guesses.
- MERV
- Minimum Efficiency Reporting Value — the filter-effectiveness scale. MERV 8 catches dust; MERV 11 catches pollen; MERV 13 catches most bacteria and fine particles. Higher MERV is not always better — restricted airflow damages equipment.
- Mini-Split
- See Ductless.
- Modulating
- A system that adjusts output continuously (0–100%) rather than being on/off. Modulating gas furnaces and inverter heat pumps deliver the steadiest indoor temperatures.
O
- Open-Loop System
- A geothermal configuration that pumps water from a well through the heat pump and discharges it (to a second well, pond, or drain). Less common than closed loops.
P
- Plenum
- The main air chamber attached to the supply or return side of the air handler. Ducts branch off the plenum.
- Programmable / Smart Thermostat
- A thermostat that follows a schedule (programmable) or learns and adapts (smart, e.g. ecobee, Nest). Communicating thermostats also relay diagnostic data back to the equipment.
R
- R-22 / R-410A / R-454B / R-32
- Refrigerant generations. R-22 (Freon) is banned. R-410A is being phased down in 2025+ under the AIM Act. R-454B and R-32 are the low-GWP replacements now shipping on new equipment.
- Rebate
- A cash-back incentive from a utility (Dominion Energy in most of our region) or manufacturer for installing qualifying high-efficiency equipment. Stackable with financing but not with the expired federal tax credits.
- Register
- The visible cover on a supply-air outlet. Has adjustable louvers to direct or throttle airflow.
- Return Air
- The air the blower pulls back from the house to be reconditioned. Undersized returns are one of the most common reasons a system 'can't keep up.'
S
- SEER2
- Seasonal Energy Efficiency Ratio (2023 update) — the seasonal cooling efficiency of an AC or heat pump. Federal minimums as of 2023 are 14.3 SEER2 in the Southeast (VA).
- Static Pressure
- See Duct Static Pressure.
- Split System
- The standard residential HVAC configuration: outdoor condenser + indoor air handler or furnace, connected by refrigerant lines. Distinct from a packaged unit.
- Supply Air
- The conditioned air the blower pushes into your rooms through ducts and registers.
T
- Ton (of Cooling)
- 12,000 BTU/hr of capacity. A 3-ton system provides 36,000 BTU/hr. The right size for a home comes from a Manual J calc, never square footage alone.
- TXV
- See Expansion Valve.
V
- Variable-Speed
- A motor that runs at multiple speeds instead of on/off. Variable-speed blowers move air more quietly, dehumidify better on low, and cut power consumption dramatically at part load.
- Ventilation
- The intentional exchange of indoor and outdoor air for IAQ. In tight new-construction homes it's mechanical (HRV/ERV); in older homes it's often incidental via infiltration.
- VOCs
- Volatile Organic Compounds — chemical vapors from paint, cleaners, cabinetry, flooring, and fuel combustion. Removed by ventilation + carbon filtration; NOT by MERV filters alone.
W
- WaterFurnace
- The Indiana-built geothermal heat pump manufacturer Airflow Systems installs as a premier WaterFurnace partner. Referenced throughout the site because it is the specific equipment on most of our geothermal installs.
- Wet-Bulb Temperature
- The temperature air would reach if cooled by evaporation to 100% humidity. A better predictor of comfort and cooling load than dry-bulb temperature — and the reason a humid day can feel worse than a hotter, drier one.
Z
- Zoning
- Splitting a single HVAC system into multiple thermostat-controlled zones via motorized dampers or dedicated mini-split heads. Helps with the common problem of an upstairs that runs hotter than the downstairs.
No terms match that filter. Clear the field to see all 48 entries.
Contact
Term you didn't find here?
Call (434) 979-4328 Mon–Fri 7:30 AM – 4:00 PM and an Airflow technician will translate whatever's on your estimate — no obligation.